Ventilation unit with daikin recuperation. Daikin air conditioners with fresh air mode

  • Highly efficient, energy-saving ventilation units using heat and moisture recovery from the premises.
  • Possibility to install a filter with more a high degree supply air cleaning, class F6,F7,F8.
  • The presence of a bypass valve, thanks to which it is possible to naturally cool the air in summer period.
  • Wide range of units from 150 to 2000 m3/h.
  • Reduced power consumption due to DC fans.
  • Low noise level with small dimensions.
  • Possibility to connect an air quality sensor, CO2.
  • Highly efficient heat exchanger with increased permeability and an efficiency of about 90%.
  • Provides a separate, autonomous operation and work in conjunction with air conditioning systems.
  • Lack of condensate drain, and hence the drainage system.
  • Possibility to control the anti-freeze system.
  • The ability to adjust the excess of supply air over exhaust air, up to 20%.

Additional options and accessories

DAIKIN VAM series recuperators are not equipped with frost protection. When operating ventilation units below -10 0 C, it is desirable to install frost protection, which includes:

1. Air heater.
2. Thermostat.
3. Relay.
4. Differential pressure sensor

Installation of an additional air heater is necessary when the structure is operating at temperatures below -10 degrees. Its power is initially calculated for the maximum air flow. If the air flow decreases with a decrease in the temperature outside, the following formula is used to calculate the heater power:

N= -0.33x(T+15)xL


Where: N-heater power, calculated in kW,
T-minimum design temperature for a particular region
L- air consumption in m3/h.

The heater must be controlled by a capillary thermostat (Shuft NET-5/HY) with an operating temperature range of -30 0 С to +30 0 С, via a solid state relay or a magnetic starter.

ThermostatSolid-state relays
Differential pressure transmitter PS500B
Duct heater
Price: 4200 rub Price: from 1250 rubles. Price: 2100 rubles. Price: from 2500 rubles.

A magnetic starter, unlike a relay, although it has a lower cost, also has a number of disadvantages, one of which is contact noise when the load is turned on and off. To avoid extraneous noise during the operation of the plant heater, it is desirable to install a solid state relay that is completely silent in operation. Just like heaters, relays are selected depending on the power.
If the heat exchanger is planned to be installed in a warm room, then it is advisable to additionally install air dampers at the air inlet and outlet of the unit to the street, which will open when the unit is turned on and close when it is turned off.
In order to be able to connect motorized air dampers to the unit, it is necessary to use a differential pressure sensor, the sensors of which are installed before and after the supply fan. A pressure sensor is also required when a frost protection kit is connected to the system. As a result of the operation of the fan when the unit is switched on, a pressure difference is created and the sensor sends a signal to open the air dampers and to the frost protection device.
PS500B Operating Instructions

DAIKIN air handling unit control panel

Air handling unit control panel BRC301B61 allows you to remotely control it, switch operating modes with or without a heat exchanger (relevant in the summer, when the air temperature drops at night and you can cool the room when
outside air), makes it possible to turn on the unit in the FRESH UP mode, when the air supply exceeds its exhaust by 20%, which is very important for normal operation exhaust ventilation in the kitchen, c / a and bathroom. Using the control panel, you can set a timer and adjust the volume of air supplied to the room. The display shows information about the operating mode of the unit, set timers, replacement of dust filters and the need to clean the heat exchange cassette.
The factory fan speed settings can be changed using the service settings. Using the service menu, you can select the maximum and minimum fan speeds out of 14 possible.

Price: 13 900 rubles.

Technical characteristics of recuperators DAIKIN VAM 150-2000

Parameter / Model VAM-150FA VAM-250FA VAM-350FB VAM-500FB
Price Rub 62 600
72 900
83 200
91 900
Air consumption (max) m3/h 150 250
350 500
Power consumption Tue 110 110
210
210
% 85 90 90 90
Noise level (min-max) dB(A) 20 - 27
21- 29 23 - 32 24 - 33
Supply voltage V 220-240 V, 1 phase, 50 Hz
-10 … +40°C, relative humidity no more than 80%

Parameter / Model VAM-650 FB VAM-800 FB
VAM-1000 FB
Price Rub 102 600
113 800
127 400
Air consumption (max) m3/h 650 800
1000
Power consumption Tue 260 480
480
Recovery efficiency (max) % 90 90 90
Noise level (min-max) dB(A) 27 - 34
31- 36 31 - 36
Supply voltage V 220-240 V, 1 phase, 50 Hz
Guaranteed outdoor temperature range

Parameter / Model VAM-1500 FB
VAM-2000 FB
Price Rub 141 500
251 200
Air consumption (max) m3/h 1500 2000
Power consumption Tue 900 900
Recovery efficiency (max.) % 90 90
Noise level (min-max) dB(A) 34 - 39 35 - 40
Supply voltage V 220-240 V, 1 phase, 50 Hz
Guaranteed outdoor temperature range -10 … +40°C, relative humidity max. 80%

* - in the complete set of installations with the FB index there is a bypass.

Unit dimensions


The HRV system helps create a comfortable environment by interacting with the air conditioning system. The HRV (Heat Recovery Ventilation) system returns thermal energy lost during ventilation and smooths out the change in room temperature caused by ventilation, thereby maintaining a comfortable clean environment. It also reduces the load on the air conditioning system and saves energy.

In addition, the HRV system works in conjunction with the VRV® system, Sky Air and other systems, automatically switches to ventilation mode, which increases the energy saving level. The operation of the HRV system is centrally controlled from the console remote control conditioner. This provides simple overall control of air conditioning and ventilation.

These configurations include models with a DX heat exchanger and/or - a DX heat exchanger helps protect personnel from direct action cold air flow during the heating cycle and vice versa. The high static pressure increases the design flexibility of the system.

1. ENERGY EFFICIENCY

More than 30% block size reduction

The use of a high quality paper (HEP) element and optimized design of the fan and airflow channels resulted in a very compact unit while maintaining the 28% reduction in A/C load achieved by previous models. The height of the main unit has been reduced by 40mm, making it easy to install in space-constrained areas such as false ceilings.

Reducing the load on the air conditioning system by an average of 28% (maximum 40%) includes:
- 20% due to operation in full heat exchange mode (compared to conventional fans)
- 6% due to automatic switching of the ventilation mode
- another 2% by pre-cooling and heating control (reduces the load on the air conditioning system without an operating HRV system, when the air remains clean for a certain time after switching on.)

Note: The above values ​​are subject to change depending on the weather and other conditions. environment at the location of the unit

Signature high quality paper (HEP) element

The heat exchanger element is made of high quality paper (HEP), which has excellent moisture absorbing and moisturizing properties. This allows the heat exchanger to quickly recover the heat contained in the latent heat (steam). The element is made of flame retardant material treated with anti-deformation agent.

Operation of the heat exchanger element

Automatic switching to efficient schemes work

During operation, it automatically switches to optimal scheme according to current prevailing conditions



2. DESIGN FLEXIBILITY

Operation at outdoor temperatures down to -15°C

If the outdoor air intake temperature drops below -10°C, the unit will go into intermittent operation, which prevents the heat exchanger element from freezing and causing condensation to form in the unit.

Intermittent operation = thermistor (standard equipment) in the unit detects the outside air temperature. The operation of the unit changes according to the determined temperature.

Compact dimensions

The compact size of the HRV unit allows it to be easily installed in narrow spaces between suspended ceilings and ceilings, as well as in irregularly shaped spaces.


Compact design

The unit can be mounted horizontally or upside down, depending on the installation location. A 450 mm square inspection hatch makes it easy to make heat exchanger elements.


Quiet operation

Sound pressure levels are very low at 20.5dBA (VAM150FA)


3. CLEAN AIR

Fresh air supply

The user can select 2 fresh air modes with the remote control.


Prevention of dust settling

Prevents dust settling due to direct .

Filter cleaning

The signal from the remote control indicates when the air filter needs to be cleaned.

CHARACTERISTICS OF THE VKM SYSTEM

1. ENERGY EFFICIENCY

Natural cooling at night allows you to save energy at night when the air conditioning system is turned off. By ventilating the rooms where the office equipment is located, which raises the temperature in the rooms, the night mode can reduce the cooling load when the air conditioning system is turned on in the morning.

Freecooling at night only works when connected to multi-unit or VRV® systems.

Freecooling at night is factory set to “disabled” but can be enabled by your Daikin dealer upon request.

Effective preparation outside air via heat exchanger and cooling/heating changeover mode

Indoor unit with outdoor air preparation.

With outside air, the temperature can be brought up to a temperature close to the room temperature with a minimum cooling capacity.

2. DESIGN FLEXIBILITY

High static pressure

Modifications to the fan design, including the use of multi-arc blades, a thinner volute and optimal angle fan spirals, improve work efficiency. Significantly higher static pressure is achieved through improved fan performance. This reduces unit placement restrictions and provides flexible duct design.

Connectivity of indoor units

Connectable indoor units can be up to 130% of the capacity of the outdoor unit

HRV Ventilation units with heat recovery

VAM150FVAM250FVAM350FVAM500FVAM650FVAM800FVAM1000FVAM1500FVAM2000F
1621 € 1919 € 2190 € 2423 € 2702 € 2981 € 3354 € 3726 € 6615 €

HRV plus Air handling units with heat recovery, cooling and humidification

HRV plus DIRECT COOLING AND HUMIDIFYING
VKM50GMVKM80GMVKM100GM
9502 € 10433 € 10900 €

HRV plus DIRECT COOLING
VKM50GVKM80GVKM100G
9129 € 9874 € 10153 €

The HRV system helps create a comfortable environment by interacting with the air conditioning system. The Daikin HRV (Heat Recovery Ventilation) system recovers the heat energy lost during ventilation and smooths out the change in room temperature caused by ventilation, thereby maintaining a comfortable clean environment. It also reduces the load on the air conditioning system and saves energy.

In addition, the HRV system works in conjunction with the VRV® system, Sky Air and other systems Daikin air conditioning, automatically switches to ventilation mode, which increases the energy saving level. The operation of the HRV system is centrally controlled from the remote control of the air conditioner. This provides simple overall control of air conditioning and ventilation.

These configurations include models with a DX coil and/or humidifier - the DX coil helps protect personnel from direct exposure to cold airflow during the heating cycle and vice versa. The high static pressure increases the design flexibility of the system.

1. ENERGY EFFICIENCY

More than 30% block size reduction

The use of a high quality paper (HEP) element and optimized design of the fan and airflow channels resulted in a very compact unit while maintaining the 28% reduction in A/C load achieved by previous models. The height of the main unit has been reduced by 40mm, making it easy to install in space-constrained areas such as false ceilings.

Reducing the load on the air conditioning system by an average of 28% (maximum 40%) includes:
- 20% due to operation in full heat exchange mode (compared to conventional fans)
- 6% due to automatic switching of the ventilation mode
- another 2% by pre-cooling and heating control (reduces the load on the air conditioning system without an operating HRV system, when the air remains clean for a certain time after switching on air conditioner.)

Note: The above values ​​may vary depending on the weather and other environmental conditions at the location where the unit is installed.

Signature high quality paper (HEP) element

The heat exchanger element is made of high quality paper (HEP), which has excellent moisture absorbing and moisturizing properties. This allows the heat exchanger to quickly recover the heat contained in the latent heat (steam). The element is made of flame retardant material treated with anti-deformation agent.

Operation of the heat exchanger element


Automatic switching to efficient work patterns

During operation, automatic switching to the optimal scheme takes place in accordance with the current dominant conditions



2. DESIGN FLEXIBILITY

Operation at outdoor temperatures down to -15°C

If the outdoor air intake temperature drops below -10°C, the unit will go into intermittent operation, which prevents the heat exchanger element from freezing and causing condensation to form in the unit.

Intermittent operation = thermistor (standard equipment) in the unit detects the outside air temperature. The operation of the unit changes according to the determined temperature.

Compact dimensions

The compact size of the HRV unit allows it to be easily installed in narrow spaces between suspended ceilings and ceilings, as well as in irregularly shaped spaces.

Compact design

The unit can be mounted horizontally or upside down, depending on the installation location. The 450 mm square inspection hatch makes it easy to carry out service and replacement heat exchanger element.

Quiet operation

Sound pressure levels are very low at 20.5dBA (VAM150FA)

3. CLEAN AIR

Fresh air supply

The user can select 2 fresh air modes with the remote control.

Prevention of dust settling

Prevents dust settling due to direct installation of air ducts.

Filter cleaning

The signal from the remote control indicates when the air filter needs to be cleaned.




CHARACTERISTICS OF THE VKM SYSTEM


1. ENERGY EFFICIENCY

Natural cooling at night allows you to save energy at night when the air conditioning system is turned off. By ventilating the rooms where the office equipment is located, which raises the temperature in the rooms, the night mode can reduce the cooling load when the air conditioning system is turned on in the morning.

Freecooling at night only works when connected to multi-unit or VRV® systems.

Freecooling at night is factory set to “disabled” but can be enabled by your Daikin dealer upon request.

Efficient outdoor air preparation with heat exchanger and cooling/heating changeover mode

Indoor unit with outdoor air preparation.

With outside air, the temperature can be brought up to a temperature close to the room temperature with a minimum cooling capacity.


2. DESIGN FLEXIBILITY

High static pressure

Modifications to the fan design, including the use of multi-arc blades, a thinner volute and an optimized fan helix angle, result in increased efficiency. Significantly higher static pressure is achieved through improved fan performance. This reduces unit placement restrictions and provides flexible duct design.


Connectivity of indoor units

Connectable indoor units can be up to 130% of the capacity of the outdoor unit

Prices for Daikin air handling units

HRV Ventilation units with heat recovery

VAM150F VAM250F VAM350F VAM500F VAM650F VAM800F VAM1000F VAM1500F VAM2000F
1621 € 1919 € 2190 € 2423 € 2702 € 2981 € 3354 € 3726 € 6615 €

HRV plus Air handling units with heat recovery, cooling and humidification

HRV plus DIRECT COOLING AND HUMIDIFYING
VKM50GM VKM80GM VKM100GM
9502 € 10433 € 10900 €

HRV plus DIRECT COOLING
VKM50G VKM80G VKM100G
9129 € 9874 € 10153 €

Daikin VAM-FB– supply and exhaust ventilation unit with heat recovery series HRV, which can be used as part of a multi-zone air conditioning system VRV Daikin. Great option for an apartment country house or office. Supply and exhaust ventilation units HRV corporations Daikin allow you to create ventilation systems with simple and convenient control, with a heat exchange efficiency of up to 80%. The heat exchange unit included in the unit minimizes energy losses in winter period year, transferring the heat of the exhaust air to the cold (supply) air flow.

The Daikin VAM1000F/FA/FB air handling unit with VKM heat recovery performs not only temperature exchange between air flows, but also humidity exchange, and thus “stabilizes” the air in the room. The possibility of air humidification is in many cases a decisive factor when choosing Daikin units.

At the same time, it is possible to avoid excessive dryness of the air in the room, since the special material of the heat exchange unit leaves the room not only warm, but also up to 60% moisture. During the summer season, the installation HRV reduces by an average of 20% heat load to the air conditioning system. This makes it possible to use air conditioners with a lower cooling capacity for the same rooms.

A single control of air conditioning and ventilation will save a few more percent. Additional energy savings can be achieved by using the "Precool/Heat" mode. Under this mode, the start of the ventilation system is delayed in relation to the operation of the air conditioner, which reduces the time required for cooling / heating the room.

Distinctive features: Compact and energy saving HRV ventilation system has a wide range of models (9 models with air flow from 150 to 2000 m3/h). This is a very good solution for ventilation of apartments and offices.
Permissible outdoor air temperature range from -15 °С to +50 °С. Expanded scope with the possibility of saving energy.
Low noise level. The new Multi Arc Blade Fan provides a noise level of 27 dBA (for VAM150FA), which allows you to install a ventilation unit even in bedrooms
More efficient and compact heat exchanger. The rate of latent heat and water vapor transfer has been increased, which has made it possible to reduce the dimensions of the heat exchanger by 25% compared to the previous model.
Fresh Up mode eliminates entry into the room unpleasant odors from the toilet and cold air.
Joint operation of the air conditioner and ventilation is possible, which increases the efficiency of the climate system and allows you to control: joint start-up or shutdown; the possibility of ventilation control independent of the air conditioner; changing the ventilation mode (auto/heat exchange mode/no heat exchange); indication of filter contamination; change in air flow rate (high/low); activating the air pre-treatment function before starting the air conditioner.


ventilation unit Daikin HRV has three ventilation modes, which can be selected by the remote controller of the unit or the remote controller of the indoor unit VRV: full heat exchange mode, when the supply and exhaust air exchange heat and moisture; bypass mode, when supply air is directly supplied to the premises, bypassing the heat exchange unit; auto mode when the room temperature is automatically selected optimal mode work.

Using a bond paper element ( HEP) and optimized design of the fan and airflow ducts resulted in a very compact unit while maintaining the 28% reduction in air conditioning load achieved by previous models.

The height of the main unit has been reduced by 40mm, making it easy to install in space-constrained areas such as false ceilings. Reducing the load on the air conditioning system by an average of 28% (maximum 40%) includes: 20% due to operation in full heat exchange mode (compared to conventional fans) 6% due to automatic changeover of ventilation mode another 2% due to pre-cooling control and heating (reduces the load on the air conditioning system without a running system HRV when the air remains clean for a certain time after the air conditioner is turned on.)

Two speeds can be selected using the installation remote control HRV or indoor unit remote control VRV. Selecting the ventilation mode The remote control can be used to set the ventilation mode, in which the supply air supply exceeds the exhaust air flow rate and excludes the possibility of unpleasant odors from the kitchen or toilet entering the room. By changing the remote control settings, you can set the ventilation mode so that the extract air flow is greater than the supply air. In addition to remote control HRV or indoor unit VRV, installation HRV easily integrated into the centralized control system VRV II.

Pre-cooling or pre-heating modes are provided, according to which ventilation is switched on with a certain delay in relation to the moment the air conditioner is started. This significantly improves system efficiency and reduces power consumption.

Daikin Europe NVis a subsidiary of Daikin Industries Ltd. It is the head office for Europe, Russia, Africa and the Middle East. Funded and supported by a Japanese parent company.

Daikin ( Daikin ) was founded in 1973 (Belgium) due to the growing demand in Europe for quality, reliable air conditioning systems. Initially, it was a small assembly plant, which in a short time transformed into the most modern air conditioning plant in Europe (its area is more than 150.000 sq.m.) It produces products perfectly adapted to the specifics Russian market. Daikin equipment is supplied to many countries around the world.

PRODUCTS

Daikin Europe NV designs and manufactures high-tech air conditioning equipment for domestic and industrial use as well as air cleaners and ventilation systems , which take the exhaust air from the room and supply Fresh air from the street.

Daikin ventilation with heat recovery changes the temperature and humidity of the supply air according to the indoor climate. Due to this, a balance is achieved between indoor and outdoor conditions and the load on the air conditioning system is significantly reduced.
Heat Recovery Ventilation (HRV) units can operate independently or together with the entire air conditioning system. The equipment is used in residential, office and commercial premises, sports facilities, as well as restaurants, cafes and other similar facilities.

Advantages of the HRV system

  • possible installation in false ceiling or in the floor
  • the most compact equipment in its class
  • efficient heat exchanger
  • new model has a higher heat exchanger efficiency (latent heat and steam removal efficiency)
  • moisture removal
  • twice the moisture absorption rate
  • central and centralized control
  • reduction of heat load on air conditioners by 28%

DAIKIN PRODUCT QUALITY

Daikin equipment stands for energy efficiency, energy savings, ease of placement, environmental friendliness, ease of operation, optimal configuration and compatibility of climate equipment.

The recognized quality of a company's products is determined by special attention which is given to the quality of work performed at all stages of production and after-sales service of Daikin equipment. The quality of products is confirmed by ISO9001 (guarantees product quality) and EUROVENT certificates (members of this organization voluntarily provide their products for testing and evaluation in independent laboratories of the EUROVENT European Quality Assurance Institute - the only independent certification body for refrigeration and air conditioners).

Ventilation units with heat recovery

Specifications:

  • Compact and energy saving HRV ventilation system has a wide range of models (9 models with air flow from 150 to 2000 m3/h). This is a very good solution for ventilation of apartments and offices.
  • Permissible outdoor air temperature range from -15 °С to +50 °С. The scope of application has been expanded with the possibility of saving energy.
  • Low noise level. The new Multi Arc Blade Fan provides a noise level of 27 dBA (for VAM150FA), which allows you to install a ventilation unit even in bedrooms.
  • More efficient and compact heat exchanger. The rate of latent heat and water vapor transfer has been increased, which has made it possible to reduce the dimensions of the heat exchanger by 25% compared to the previous model.
  • The Fresh Up mode eliminates the ingress of unpleasant odors from the toilet and cold air through leaks into the room.
  • Joint operation of air conditioning and ventilation is possible, which increases the efficiency of the climate system and allows you to control:
  1. joint start or shutdown;
  2. the possibility of ventilation control independent of the air conditioner;
  3. changing the ventilation mode (auto/heat exchange mode/no heat exchange);
  4. indication of filter contamination;
  5. change in air flow rate (high/low);
  6. activating the air pre-treatment function before starting the air conditioner.

*- The sound pressure level is measured in the heat exchange mode.

HRV Plus

Ventilation units with heat recovery, cooling and humidification

Specifications:

  • Humidifier and cooler built into the ventilation unit with heat recovery.
  • Increased free head due to improved fan performance.
  • Heat removal function: the heat accumulated in the room during the day is removed at night.
  • The air handling units are compatible with existing DAIKIN control systems.
  • VKM units can only be connected to VRV outdoor units: RXYSQ-P, RXY(H)QP,
  • REY(H)Q-P, RTSYQ-P and RWEYQ-P(R).
  • The ventilation unit control is designed to work together with the indoor units of the VRV system. Installing VKM and indoor unit controlled from one remote control.

AHU

Central air conditioners (ventilation)

Due to the variety of configurations and types of execution, flexibility in the selection of equipment, Daikin central air conditioners can be used:

  • in the domestic sector
  • in retail and commercial areas
  • in public and public institutions
  • at industrial and research facilities
  • in food production
  • medicine and pharmaceuticals.

Daikin's standard range of air handling units (D‑AHU) includes 27 standard unit sizes with air capacities ranging from 1,100 to 124,000 m3/h. In addition, it is possible to manufacture individual sizes with a step of 50 mm, and this does not lead to an increase in cost.

In 2011, Daikin launched the new model range called Easy AHU. The productivity of new products is from 500 to 30,000 m3/hour. Easy AHU units are structurally simpler and, accordingly, cheaper than standard ones.

energy efficiency

All installations are designed with high demands to energy efficiency. When developing equipment, the thermophysical properties of heat exchange surfaces, the efficiency of electric motors, the degree of filtration, insulation, reduction of friction and pressure drops of the air flow are taken into account. The energy efficiency of installations can be further increased by heat recovery.

Efficient air treatment

Depending on the requirements for air purity, central air conditioners are equipped with filters of various degrees of efficiency:

  • synthetic corrugated
  • flat in aluminum steel mesh
  • compact and soft bag
  • absorption
  • deodorizing

All filters are mounted on commercially available frames with seals.

To prevent dust from entering the air passage when performing Maintenance, the filters are removed from the contaminated side.

The units can be equipped different types and models of humidifiers. Options are available with fully removable humidifiers or with a removable surface evaporation humidifier section.

The units may include heat exchangers with an intermediate coolant or freon, electric heaters, fans, heat recuperators, gas-burners, silencers, controls, automation and security.

D‑AHU units can be combined with chillers and large condensing units, including Daikin inverter condensing units with ozone friendly R‑410A refrigerant.

Variety of designs

The overall dimensions of the central air conditioner can be selected depending on the actual installation conditions. The design is based on a supporting frame and profiles made of aluminum (or anodized aluminum, which the best way suitable for working in aggressive environments) with a section of 40x40 or 60x60 mm. There are modifications of profiles with a section of 60x60 mm with a thermal insulating insert to reduce heat loss. Profiles with oval inner surface recommended for use in the food industry, medicine, other areas with special requirements to hygiene.

Panels can be flat, 25 and 46 mm thick, or stepped, 42 and 62 mm thick.

Stepped panels allow you to get a flat surface inside the product. Insulation is made of polyurethane foam (40-50 kg/m3) or fibrous mineral wool(90 kg/m3).

Daikin central air conditioners use components produced by companies that are world leaders in their fields: Daikin, Siemens, Belimo, Nicontra, Comefri, Gebhardt.


Modern management

The units are completed with a control cabinet based on a digital controller with all power and control connections. Upon request, the units can be supplied with sensors, servo drives and protective devices. Along with automation, it is possible to order elements of hydraulic piping for water heat exchangers: two- and three-way control valves, pumps, shut-off valves.

Rapid design, installation, commissioning