Daikin VAM350FB (supply and exhaust with recuperation). Daikin air conditioners with supply ventilation mode DAIKIN air handling unit control panel

Daikin Europe NVis a subsidiary of Daikin Industries Ltd. It is the head office for Europe, Russia, Africa and the Middle East. Funded and supported by a Japanese parent company.

Daikin ( Daikin ) was founded in 1973 (Belgium) due to the growing demand in Europe for high-quality reliable air conditioning systems. Initially it was a small assembly plant, which in a short time was transformed into the most modern plant for the production of air conditioners in European countries (its area is more than 150,000 sq.m.) It produces products perfectly adapted to the characteristics Russian market... Daikin equipment is supplied to many countries around the world.

PRODUCTS

Daikin Europe NV designs and manufactures high-tech equipment for air conditioning for residential and industrial use as well as air purifiers and ventilation systems, which take exhaust air from the room and supply fresh air from the street.

Daikin heat reclaim ventilation modifies the temperature and humidity of the supply air according to the room climate. Due to this, a balance is achieved between indoor and outdoor conditions and the load on the air conditioning system is decently reduced.
The units of the heat recovery ventilation system (HRV system) can be operated independently or together with the entire air conditioning system. The equipment is used in residential, office and commercial premises, sports facilities, as well as restaurants, cafes and other similar facilities.

Advantages of the HRV system

  • installation in false ceiling or in the floor
  • the most compact equipment in its class
  • efficient heat exchange element
  • new model has a higher efficiency of the heat exchanger (efficiency of extraction of latent heat and water vapor)
  • moisture removal
  • twice the rate of moisture absorption
  • central and centralized management
  • reduction of heat load on air conditioners by 28%

DAIKIN PRODUCT QUALITY

Daikin equipment is energy efficiency, energy savings, ease of placement, environmental friendliness, ease of management, optimal configuration and compatibility of climate control equipment.

The recognized quality of a company's products is determined by special attention, which is devoted to the quality of work performed at all stages of production and after-sales service of Daikin equipment. The quality of products is confirmed by certificates ISO9001 (guarantees product quality) and EUROVENT (members of this organization voluntarily submit their products for testing and evaluation in independent laboratories of the European Institute for Quality Control EUROVENT - the only independent certification body for refrigeration and air conditioning equipment).

Air handling units with heat recovery

Specifications:

  • The compact and energy-saving HRV ventilation system has a wide the lineup(9 models with air flow rates from 150 to 2000 m3 / h). This is a very good solution for ventilation of apartments and offices.
  • The permissible range of outdoor air temperature is from -15 ° С to +50 ° С. The scope of application is expanded with the possibility of saving energy.
  • Low noise level. The new Multi Arc Blade Fan provides a noise level of 27 dBA (for VAM150FA), which allows the ventilation unit to be installed even in sleeping rooms.
  • More efficient and compact heat exchanger. The rate of transfer of latent heat and water vapor has been increased, which made it possible to reduce the size of the heat exchanger by 25% compared to the previous model.
  • Fresh Up mode eliminates spills unpleasant odors from the toilet and cold air through leaks into the room.
  • Combined operation of the air conditioner and ventilation is possible, which increases the efficiency of the climate system and allows you to control:
  1. joint start-up or shutdown;
  2. the possibility of ventilation control independent of the air conditioner;
  3. changing the ventilation mode (auto / heat exchange mode / without heat exchange);
  4. filter contamination indication;
  5. changing the air flow rate (high / low);
  6. by activating the air pre-treatment function before starting the air conditioner.

* - The sound pressure level is measured in the heat exchange mode.

HRV plus

Air handling units with heat recovery, cooling and humidification

Specifications:

  • A humidifier and a cooler integrated into a heat recovery ventilation unit.
  • Increased free head thanks to improved fan performance.
  • Heat removal function: the heat accumulated in the room during the day is removed at night.
  • Air handling units are compatible with existing DAIKIN control systems.
  • VKM units can only be connected to VRV outdoor units: RXYSQ-P, RXY (H) QP,
  • REY (H) Q-P, RTSYQ-P and RWEYQ-P (R).
  • The control of ventilation units is designed to work in conjunction with the indoor units of the VRV system. The VKM unit and the indoor unit are controlled from one remote control.

AHU

Central air conditioners (ventilation)

Due to the variety of configurations and types of performance, flexibility in the selection of equipment, Daikin air handling units can be used:

  • in the household sector
  • in retail and commercial areas
  • in public and government agencies
  • at industrial and research facilities
  • in food production
  • medicine and pharmaceuticals.

Daikin's standard range of air handling units (D ‑ AHU) includes 27 standard unit sizes with air flow rates ranging from 1,100 to 124,000 m3 / h. In addition, it is possible to manufacture individual sizes with a step of 50 mm, and this does not lead to an increase in cost.

In 2011, Daikin launched a new range of units called Easy AHU. The productivity of new products is from 500 to 30,000 m3 / hour. Easy AHU units are structurally simpler and, accordingly, cheaper than standard units.

Energy efficiency

All installations are designed taking into account high demands to energy efficiency. When developing equipment, the thermophysical properties of the heat exchange surfaces, the efficiency of electric motors, the degree of filtration, insulation, reduction of friction and pressure drops of the air flow are taken into account. The energy efficiency of the units can be further increased by heat recovery.

Efficient air handling

Depending on the requirements for air purity, central air conditioners are equipped with filters of various degrees of efficiency:

  • synthetic corrugated
  • flat in aluminum steel mesh
  • compact and soft bag
  • absorption
  • deodorant

All filters are mounted on commercially available frames with seals.

To avoid dust entering the air duct when performing Maintenance, the filters are removed from the dirty side.

Installations can be completed different types and humidifier models. Versions with fully removable humidification devices or removable evaporative humidifier section are available.

The units may include heat exchangers with an intermediate heat carrier or freon, electric heaters, fans, heat recuperators, gas-burners, silencers, controls, automation and security.

D ‑ AHU units can work together with chillers and large condensing units, including - with Daikin inverter condensing units using ozone safe refrigerant R ‑ 410A.

Variety of designs

The overall dimensions of the air handling unit can be selected depending on the actual installation conditions. The design is based on a supporting frame and profiles made of aluminum (or anodized aluminum, which the best way suitable for work in aggressive environments) with a section of 40x40 or 60x60 mm. There are modifications of profiles with a cross section of 60x60 mm with a thermal insulating insert to reduce heat loss. Oval profiles inner surface are recommended for use in the food industry, medicine, and other areas with special requirements to hygiene.

The panels can be flat, 25 and 46 mm thick, or stepped, 42 and 62 mm thick.

Stepped panels provide a flat surface inside the product. Insulation is made of polyurethane foam (40-50 kg / m3) or fibrous mineral wool(90 kg / m3).

Daikin central air conditioners use components produced by companies that are world leaders in their fields: Daikin, Siemens, Belimo, Nicontra, Comefri, Gebhardt.


Modern management

The units are equipped with a control cabinet based on a digital controller with all power and control connections. The scope of supply of the units, on request, can include sensors, servo drives and protective devices... Along with automation, it is possible to order elements of the hydraulic piping of water heat exchangers: two- and three-way control valves, pumps, shut-off and control valves.

Fast design, installation, commissioning

RUB 36,900

Wall mounted air conditioner Daikin ATYN25L / ARYN25L

WITH automatic mode... With heating mode. Heating power 2800 W. Noise level 25 dB. With self-diagnosis function. Type of indoor unit- wall-mounted. . Cooling power 2500 W. With a remote control. With auto-restart. Refrigerant - R410A. Serviced area 25 m 2. The maximum length of communications is 20 m. The type of air conditioner is split-system. With on / off timer.

buy v online store Ziwo.ru

loan possible

Photo

RUB 48 800

Air conditioner Daikin ATYN25L / ARYN25L Nord-40

With a serviced area of ​​25 m 2. Autorestart. Auto mode. Mode supply ventilation ... With a noise level of 25 dB. On / off timer. With a heating power of 2800 W. Air conditioner type - split systems. Indoor unit type - wall-mounted. With a cooling capacity of 2500 W. With a maximum communication length of 20 m. Self-diagnosis. Heating mode. Refrigerant - R410A. Remote control.

buy v online store MirCli.ru

loan is possible | pickup possible

Photo

RUB 48 800

Daikin ATYN25L / ARYN25L Nord-40 air conditioner 2.6 kw

Indoor unit type - wall-mounted. With heating mode. Noise level 25 dB. With self-diagnosis function. With supply ventilation mode... Cooling power 2500 W. With a remote control. The maximum length of communications is 20 m. Heating power is 2800 watts. Air conditioner type - split systems. Serviced area 25 m 2. With auto-restart. Refrigerant - R410A. With on / off timer. With automatic mode.

buy v online store Proclimatgroup.ru

loan possible

Photo

RUB 35,040

Wall mounted air conditioner Daikin ATYN25L / ARYN25L Nord-30

Supply ventilation mode... Indoor unit type - wall-mounted. Heating mode. Self-diagnosis. Autorestart. With a heating power of 2800 W. Air conditioner type - split systems. Refrigerant - R410A. With a maximum length of communications 20 m. With a serviced area of ​​25 m 2. Remote control. With a noise level of 25 dB. On / off timer. Auto mode. With a cooling capacity of 2500 W.

v online store Ziwo.ru

loan possible

Photo

RUB 37,900

Air conditioner Daikin ATYN25L / ARYN25L

With heating mode. Noise level 25 dB. Heating power 2800 W. With supply ventilation mode... Cooling power 2500 W. Air conditioner type - split systems. With auto-restart. The maximum length of the lines is 20 m. The refrigerant is R410A. With automatic mode. Indoor unit type - wall-mounted. With a remote control. Serviced area 25 m 2. With on / off timer. With self-diagnosis function.

v online store MirCli.ru

loan is possible | pickup possible

Photo

RUB 47 800

Daikin ATYN25L / ARYN25L Nord-30 air conditioner 2.6 kw

Indoor unit type - wall-mounted. Air conditioner type - split systems. With a maximum communication length of 20 m. Heating mode. On / off timer. Supply ventilation mode. Self-diagnosis. With a cooling capacity of 2500 W. Auto mode. Refrigerant - R410A. With a heating power of 2800 W. Autorestart. With a serviced area of ​​25 m 2. With a noise level of 25 dB. Remote control.

v online store Proclimatgroup.ru

loan possible

Photo

35 400 rub.

Wall mounted air conditioner Daikin ATYN25L / ARYN25L Nord-40

With self-diagnosis function. With auto-restart. Refrigerant - R410A. With on / off timer. With a remote control. Heating power 2800 W. Cooling power 2500 W. With supply ventilation mode. Air conditioner type - split systems. With automatic mode. Serviced area 25 m 2. Indoor unit type - wall-mounted. The maximum length of communications is 20 m. With heating mode. Noise level 25 dB.

v online store Ziwo.ru

loan possible

Photo

RUB 47 800

Air conditioner Daikin ATYN25L / ARYN25L Nord-30

Remote control. With a cooling capacity of 2500 W. With a maximum communication length of 20 m. Autorestart. Air conditioner type - split systems. With a noise level of 25 dB. Supply ventilation mode. With a serviced area of ​​25 m 2. Auto mode. Refrigerant - R410A. Heating mode. Indoor unit type - wall-mounted. With a heating power of 2800 W. Self-diagnosis. On / off timer.

v online store MirCli.ru

loan is possible | pickup possible

Photo

RUB 49 800

Daikin ATYN35L / ARYN35L Nord-30 air conditioner 3.5 kw

Maximum communication length 20 m. With self-diagnostics function. Refrigerant - R410A. Noise level 27 dB. With auto-restart. Indoor unit type - wall-mounted. With supply ventilation mode. With automatic mode. Serviced area 33 m 2. Cooling power 3300 W. With on / off timer. With heating mode. Heating power 3400 W. With a remote control. Air conditioner type - split systems.

v online store Proclimatgroup.ru

loan possible

Photo

RUB 37 160

Wall split system Daikin ATYN35L / ARYN35L Nord-30

Indoor unit type - wall-mounted. With a serviced area of ​​33 m 2. Self-diagnosis. Refrigerant - R410A. Heating mode. Auto mode. Supply ventilation mode. With a cooling capacity of 3300 W. Remote control. Autorestart. With a heating power of 3400 W. Air conditioner type - split systems. With a noise level of 27 dB. With a maximum communication length of 20 m. On / off timer.

v online store Ziwo.ru

loan possible

Photo

RUB 39,900

Air conditioner Daikin ATYN35L / ARYN35L

Indoor unit type - wall-mounted. The maximum length of communications is 20 m. With heating mode. Heating power 3400 W. Serviced area 33 m 2. With supply ventilation mode. With self-diagnosis function. With a remote control. Air conditioner type - split systems. With auto-restart. Refrigerant - R410A. Noise level 27 dB. Cooling power 3300 W. With automatic mode. With on / off timer.

v online store MirCli.ru

loan is possible | pickup possible

Photo

RUB 67 800

Daikin ATYN50L / ARYN50L Nord-40 air conditioner 5 kw

With a serviced area of ​​53 m 2. Indoor unit type - wall-mounted. Heating mode. Self-diagnosis. Autorestart. Auto mode. Air conditioner type - split systems. Supply ventilation mode. With a heating power of 5500 W. With a cooling capacity of 5300 W. Refrigerant - R410A. Remote control. With a noise level of 34 dB. With a maximum communication length of 20 m. On / off timer.

v online store Proclimatgroup.ru

loan possible

Photo

RUB 39,300

Wall split system Daikin ATYN35L / ARYN35L

Country: Japan; Manufacturer: Japan; Warranty: 3 years; INDOOR UNIT: ATYN35L; Cold, kW: 3.3; Heat, kW: 3.47; Cooling consumption, kW: 1.08; Heating consumption, kW: 1.08; Energy efficiency EER Cooling: 3.06; Energy efficiency COP Heating: 3.54; Air consumption Cooling, mh: 633; Air consumption Heating, mh: 633; Noise level int. bl. Cooling, dBa: 27; Noise level int. bl. Heating, dBA: 27; Max length of the track height difference, m: 20; d pipes of the freon line,: 6.35 9.5; Dimensions (edit)

v online store Ziwo.ru

loan possible

Photo

RUB 49 800

Air conditioner Daikin ATYN35L / ARYN35L Nord-30

Indoor unit type - wall-mounted. Heating mode. With a serviced area of ​​33 m 2. Self-diagnosis. Autorestart. With a heating power of 3400 W. Supply ventilation mode. Auto mode. Air conditioner type - split systems. With a noise level of 27 dB. With a cooling capacity of 3300 W. Refrigerant - R410A. Remote control. With a maximum communication length of 20 m. On / off timer.

v online store MirCli.ru

loan is possible | pickup possible

Photo

RUB 66 800

Daikin ATYN50L / ARYN50L Nord-30 air conditioner 5 kw

Serviced area 53 m 2. Indoor unit type - wall-mounted. The maximum length of communications is 20 m. With heating mode. Noise level 34 dB. With supply ventilation mode. Cooling capacity 5300 W. With self-diagnosis function. With a remote control. Heating power 5500 W. Air conditioner type - split systems. With auto-restart. Refrigerant - R410A. With automatic mode. With on / off timer.

v online store Proclimatgroup.ru

loan possible

Photo

RUB 37,510

Wall split system Daikin ATYN35L / ARYN35L Nord-40

Country: Japan; Manufacturer: Malaysia; Warranty: 3 years; Cold, kW: 3.30; Heat, kW: 3.47; Consumption when cooling, kW: 1,080; Consumption at heating, kW: 0.980; Energy efficiency EER Cooling: 3.06; Energy efficiency COP Heating: 3.54; Annual Energy Consumption, kWh: 540; Air consumption Cooling, mh: 633; Air consumption Heating, mh: 633; Noise level int. bl. Cooling, dBa: 27; Noise level int. bl. Heating, dBA: 27; Max length of the track height difference, m: 2010; d pipes of the freon line,

v online store Ziwo.ru

loan possible

  • Highly efficient, energy saving ventilation units using heat and moisture recovery from the premises.
  • The ability to install a filter with more high degree supply air cleaning, class F6, F7, F8.
  • The presence of a bypass valve, thanks to which it is possible to naturally cool the air in summer period.
  • Wide range of units from 150 to 2000 m3 / h.
  • Reduced energy consumption due to DC fans.
  • Low noise level with small dimensions.
  • Possibility of connecting an air quality sensor, CO2.
  • Highly efficient heat exchanger with increased permeability and efficiency of about 90%.
  • Provided for separate, autonomous work and work in conjunction with air conditioning systems.
  • Lack of drainage of condensate, and therefore of the drainage system.
  • Possibility to control the anti-freeze system.
  • The possibility of adjusting the excess of the supply air volume over the extract air, up to 20%.

Additional options and accessories

Recuperators DAIKIN VAM series are not equipped with antifreeze protection. When operating ventilation installations below -10 0 С, an anti-freeze protection installation is desirable, which includes:

1. Air heater.
2. Thermostat.
3. Relay.
4. Differential pressure sensor

Installation of an additional air heater is necessary when the structure is operating at temperatures below -10 degrees. Its power is initially calculated for the maximum air flow. If the air consumption decreases with a decrease in the outdoor temperature, the formula is used to calculate the power of the heater:

N = -0.33x (T + 15) xL


Where: N- the power of the heater, calculated in kW,
T-minimum design temperature for a specific region,
L- air consumption in m3 / hour.

The heater must be controlled by a capillary thermostat (Shuft NET-5 / HY) with an operating temperature range of -30 0 С to +30 0 С, through a solid-state relay or a magnetic starter.

ThermostatSolid state relay
Differential pressure transmitter PS500B
Duct heater
Price: 4200 rub Price: from 1250 rubles. Price: 2100 rub. Price: from 2500 rubles.

A magnetic starter, unlike a relay, although it has a lower cost, also has a number of disadvantages, one of which is the noise of contacts when the load is turned on and off. To avoid extraneous noise during the operation of the unit heater, it is advisable to install a solid-state relay, which is completely silent in operation. Just like heaters, relays are selected depending on the power.
If the recuperator is planned to be installed in a warm room, then it is advisable to additionally install air dampers at the air inlet and outlet from the unit to the outside, which will open when the unit is turned on and close when it is turned off.
In order to connect the air dampers with an electric drive to the unit, it is necessary to use a differential pressure sensor, the sensors of which are installed before and after the supply fan. A pressure sensor is also required when a frost protection kit is connected to the unit. As a result of the fan actuation when the unit is turned on, a pressure difference is created and the sensor gives a signal to open the air dampers and to the frost protection device.
Operating instructions PS500B

DAIKIN air handling unit control panel

Air handling unit control panel BRC301B61 allows you to remotely control it, switch operating modes with or without a recuperator (relevant in the summer, when the air temperature drops at night and you can cool the room when
help street air), makes it possible to turn on the unit in FRESH UP mode, when the air supply exceeds its exhaust by 20%, which is very important for normal operation exhaust ventilation in the kitchen, bathroom and bathroom. Using the control panel, you can set a timer and regulate the amount of air supplied to the room. The display shows information about the operating mode of the unit, set timers, replacement of dust filters and the need to clean the heat exchange cassette.
The factory settings of the fan speed can be changed using the service settings. Using the service menu, you can select the maximum and minimum fan speed out of 14 possible.

Price: 13 900 rub.

Technical characteristics of recuperators DAIKIN VAM 150-2000

Parameter / Model VAM-150FA VAM-250FA VAM-350FB VAM-500FB
Price Rub 62 600
72 900
83 200
91 900
Air consumption (max) m3 / h 150 250
350 500
Power consumption W 110 110
210
210
% 85 90 90 90
Noise level (min-max) dB (A) 20 - 27
21- 29 23 - 32 24 - 33
Supply voltage V 220-240 V, 1 phase, 50 Hz
-10 ... + 40 ° C, relative humidity no more than 80%

Parameter / Model VAM-650 FB VAM-800 FB
VAM-1000 FB
Price Rub 102 600
113 800
127 400
Air consumption (max) m3 / h 650 800
1000
Power consumption W 260 480
480
Recovery efficiency (max) % 90 90 90
Noise level (min-max) dB (A) 27 - 34
31- 36 31 - 36
Supply voltage V 220-240 V, 1 phase, 50 Hz
Guaranteed outdoor temperature range

Parameter / Model VAM-1500 FB
VAM-2000 FB
Price Rub 141 500
251 200
Air consumption (max) m3 / h 1500 2000
Power consumption W 900 900
Recovery efficiency (max.) % 90 90
Noise level (min-max) dB (A) 34 - 39 35 - 40
Supply voltage V 220-240 V, 1 phase, 50 Hz
Guaranteed outdoor temperature range –10 ... + 40 ° C, relative humidity not more than 80%

* -in the complete set of units with the FB index there is a bypass.